Installing your hob in all simplicity
Hobs are delivered with a three-
conductor (2 phase + earth) H05VVF -
T105, ou H05V2V2F - T90 1mm sec-
tion cable, and must be connected to
a 230V single phase mains supply by
the intermediary of a two phase + CEI
60083 standardised earth plug, or a
single pole cut-off device with a
contact opening by at least 3,5mm.
The unit must be installed so that the
mains plug is easily accessible.
Electrical connections
The protective conductor is connected to the earth connection on the hob
and therefore must also be connected to an external earth connection .
If this cable is damaged, have it replaced by your After-Sales Service as special too-
ling is required to connect it correctly.
● Mixed and all-gas hobs
Cable H05VVF - T105
or H05V2V2F - T90
Cross section of
conductors in
mm
2
Fuse
220 V-240~- 50 Hz
All-gas and
mixed
(3+1)
1
10 A
2 gas
+ 1 halogen
+ 1 radiant
1,5
16 A
CROSS SECTION OF THE CABLE TO USE
3 conductors of which 1 is to be
earthed